Zira Andon turns every camera detection into a physical signal at the line. The instant a bad pallet is flagged, the light goes red. Operators see what the AI sees — without ever opening a dashboard.
AI vision finds the defect in milliseconds. But if that signal lives only inside a dashboard, the operator at the line never sees it. Andon closes the loop. The camera flags a bad pallet — and the light at the workstation goes red, instantly. No dashboard. No ticket. No delay.
It's the same Andon principle that's run lean factory floors for sixty years, now driven by AI instead of a pull cord.
The Zira Andon kit ships ready-to-install. Mount the light, plug the bridge into power and network, and pair it with any Zira camera. Live in under an hour.
Red / amber / green stack on an articulating bracket. High-output LED visible across the whole bay, with a swivel base that bolts to any column, beam, or workstation upright.
The brain of the kit. Pairs up to 6 Zira cameras and 1 dry-contact relay board, translating AI detections into precisely-timed contact closures. Powers the light and the relay board off a single feed.
Eight isolated relay channels. Standard config uses 3 to drive a 3-color light; the remaining 5 are spare for buzzers, secondary lights, PLC inputs, or escalation chains to multiple stations.
A Zira camera detects a state. The bridge translates the detection into a contact closure on the relay board. The relay board drives the light. End-to-end in under a second.
AI vision detects the event — bad pallet, missing block, PPE absent, etc.
Routes detections to the right relay channel. Fans out to up to 7 devices.
8 dry-contact channels. 3 close to drive R / A / G. 5 spare for buzzers or PLC.
Operator sees red / amber / green at the workstation. Decision in real time.
Map any Zira detection to any relay. The most common configurations on the floor today:
Camera flags a missing block, broken stringer, or wrong dimension at the inspection point. Light goes red and flashes — operator pulls the unit before it reaches stretch wrap.
Camera detects no hi-vis or no hard hat in a restricted bay. Amber lights up the area until the condition clears — no supervisor escalation needed.
Camera-counted output is at or above the shift goal. Steady green tells operators the line is on pace — and tells them immediately when it isn't.
Detection of a hand near the bandsaw envelope drives the relay closed. Red strobe at the station and at the supervisor desk — escalation is physical, not buried in a feed.
Andon is an extension, not a separate platform. If you already have Zira on the line, the kit pairs in software and ships within a week.
4 bolts to a column, beam, or upright. Articulating bracket aims the light wherever the operator stands.
Bridge mounts to DIN rail in any panel. Single 24V feed powers the bridge, the relay board, and the light.
Map detections to relays in the Zira console. The light is signaling within minutes of the bridge coming online.
See the Andon kit running on a live deployment. We'll wire the same setup into your facility — light, bridge, and relay board — in under an hour.